logo
Send Message
Up to 5 files, each 10M size is supported. OK
Guangzhou Sincere Information Technology Ltd. 86-176-65309551 sales@cameramodule.cn
Imaging Solution Get a Quote
Home - News - FAQ: SF-C1011USB-D3.9-720P60-L20 USB Endoscope Camera Module

FAQ: SF-C1011USB-D3.9-720P60-L20 USB Endoscope Camera Module

July 6, 2026

1. What is the SF-C1011USB-D3.9-720P60-L20?

The SF-C1011USB-D3.9-720P60-L20 is a 3.9mm integrated USB endoscope camera module using the OH01A10 sensor.

It supports YUV / MJPEG output at 1280×800@60fps, includes 4pcs 0402 LEDs, supports IP67 and provides multiple FOV and focusing range options.

2. What is the main advantage of this model?

Its main advantage is the combination of:

D3.9 compact size

Integrated structure

1280×800@60fps output

Built-in LED illumination

IP67 support

Multiple FOV options

Multiple focus range options

Type-C connection

It is designed for OEM customers who need compact size and smooth live visualization.

3. Is this an integrated or separate-type camera module?

It is listed as an ALL integrated-type module.

This is important for customers who prefer a more integrated front-end structure rather than a separate camera head and board arrangement.

4. What is the camera diameter?

The camera diameter is D3.9.

Customers should confirm that the complete probe and final housing can meet the diameter requirement of the device.

5. What sensor does it use?

The model uses the OH01A10 sensor.

It supports 1MP-class imaging and 1280×800@60fps output.

6. What resolution does it support?

The module supports 1280×800 output.

It is suitable for real-time visualization and inspection, but customers requiring 2MP, 5MP or higher image detail should evaluate other models.

7. What is the maximum frame rate?

The model supports up to 60fps at the listed maximum output.

This can help provide smoother live viewing during probe movement.

8. Is 60fps really useful for an endoscope device?

It can be useful when the camera moves continuously during operation.

Examples include handheld inspection, probe guidance, cavity navigation and applications where the user frequently changes the viewing direction.

For static observation, 60fps may be less critical.

9. Does the module support YUV and MJPEG?

Yes. The catalog lists YUV / MJPEG output.

Customers should confirm compatibility with their actual host system and software environment during sample testing.

10. Does this module include LEDs?

Yes.

It includes 4pcs 0402 LEDs for local illumination.

11. Can LED brightness be adjusted?

No.

The catalog marks dimming as No.

Customers who require adjustable brightness should evaluate another dimmable model.

12. When is fixed LED brightness acceptable?

Fixed brightness may be suitable when:

The working distance is stable

The target surface is not highly reflective

The inspection environment is consistent

The user does not need frequent brightness adjustment

Sample testing is still recommended.

13. When may fixed LEDs cause problems?

Potential problems can occur with:

Wet surfaces

Metallic surfaces

Highly reflective materials

Very short working distances

Curved reflective cavities

In these cases, customers should test for overexposure and reflection.

14. Does this module support IP67?

Yes.

The catalog marks IP67 as Yes.

15. Does IP67 mean the complete device is automatically waterproof?

No.

Final device waterproof performance depends on the complete product structure, including:

Housing

Sealing

Cable exit

Connector protection

Assembly method

Adhesive or sealing material

Final testing

16. Is this module suitable for wet industrial environments?

It can be evaluated for applications involving moisture or wet inspection conditions because the module supports IP67.

However, the complete device should still undergo final environmental and waterproof validation.

17. Can it be evaluated for medical visualization devices?

Yes, it can be evaluated as an imaging component.

Final medical device safety, compliance, cleaning requirements and certification must be handled according to the complete device and target market.

18. Is it suitable for dental or oral inspection devices?

It may be evaluated if the D3.9 size, working distance, FOV and fixed LED brightness match the application.

Customers should pay particular attention to reflection and close-range lighting.

19. Is it suitable for veterinary endoscope devices?

Yes, it can be evaluated for veterinary visualization projects.

The final choice depends on working distance, probe size, lighting, waterproof requirements and device structure.

20. Is it suitable for industrial borescopes?

Yes.

It can be evaluated for compact borescopes, cavity inspection tools, equipment inspection devices and maintenance visualization systems.

21. What FOV options are available?

The catalog lists:

75°

85°

95°

130°

These options allow customers to choose between focused observation and wider viewing.

22. Which FOV should I choose?

Consider:

Target size

Working distance

Cavity diameter

Need for navigation

Need for detail

User operation method

A narrower FOV gives a more focused view, while a wider FOV provides more surrounding context.

23. Is 130° always the best choice?

No.

A 130° FOV provides wider scene coverage, but the target may appear smaller.

Customers who need more focused detail may prefer 75°, 85° or 95°, depending on the application.

24. What focusing range options are available?

The catalog lists:

4–10mm

5–50mm

5–100mm

10–100mm

25. Which focus range is best for very close inspection?

The 4–10mm option can be evaluated for very close observation.

The final result should be confirmed by sample testing in the real application.

26. Which focus range is suitable for general close-range use?

The 5–50mm option can be evaluated for general close-range visualization.

However, the correct option depends on the real camera-to-target distance.

27. Which option is suitable when the working distance changes?

The 5–100mm or 10–100mm configurations may be evaluated when the application requires a broader working distance range.

Customers should still test actual image clarity at the nearest and farthest expected distances.

28. What is the front length?

The catalog lists a 20mm front length.

Customers should confirm whether this fits the final probe, housing or insertion structure.

29. What lens options are available?

The catalog lists plastic / glass lens options.

The exact choice should be evaluated according to optical performance, cost, durability and project requirements.

30. What is the standard cable length?

The standard cable length is 1.5m.

Customers should confirm whether this length matches the device structure and user workflow.

31. What is the maximum cable length?

The catalog lists a maximum cable length of 5m.

Longer cable use should be tested for signal stability and final system performance.

32. Does the module use Type-C?

The catalog lists Type-C connection.

Actual host compatibility should be confirmed using the customer’s intended device and software environment.

33. Can it connect directly to every Type-C phone or tablet?

Not automatically.

A Type-C connector does not guarantee compatibility with every phone, tablet or host.

Compatibility depends on the host platform, USB support, software and system configuration.

34. Is this a finished endoscope device?

No.

This is an OEM endoscope camera module.

Customers still need to evaluate final housing, mechanical protection, device assembly, host compatibility and regulatory requirements.

35. Can this model be used for AI defect inspection?

It is generally better positioned for real-time visualization than advanced AI or measurement-level inspection.

AI projects may require higher resolution, controlled lighting and application-specific image quality validation.

36. What should customers test first after receiving samples?

Customers should test:

Image smoothness during movement

Image clarity at real working distance

Selected FOV

LED brightness

Reflection on real target surfaces

IP67 performance after final device integration

Cable length stability

Type-C host compatibility

Mechanical fit of the 20mm front section

37. What is the most common mistake when choosing this model?

The most common mistake is selecting it only because it is D3.9 and supports 60fps.

Customers should also confirm:

FOV

Working distance

Lighting reflection

Need for dimming

Waterproof requirements

Cable length

Connector compatibility

Mechanical structure

38. Does this model support LED dimming?

No.

The catalog marks dimming as No.

Customers who need brightness adjustment should mention this during RFQ so another suitable model can be evaluated.

39. Can SincereFull support project customization?

Project-level customization or alternative module evaluation can be discussed based on:

Diameter

FOV

Focus range

Lens

Lighting

Cable length

Connector

Mechanical structure

Any change affecting optical performance, waterproof structure or production feasibility should be reviewed before confirmation.

40. What information should I send before asking for a quotation?

Please provide:

Application

Medical or industrial use

Required diameter

Working distance

Preferred FOV

Lighting condition

Need for dimming

Waterproof requirement

Cable length

Host device

Connector requirement

Sample quantity

Estimated production volume

Mechanical drawing if available

41. How do I know whether this model is right for my project?

Choose SF-C1011USB-D3.9-720P60-L20 when your project needs:

D3.9 integrated structure

1280×800@60fps

Built-in LEDs

IP67 support

Multiple FOV options

Multiple focus range options

Type-C connection

Compact OEM device integration

Choose another module if your project needs adjustable LED dimming, higher resolution, smaller diameter or a different structural design.

42. What is the key takeaway for buyers?

The SF-C1011USB-D3.9-720P60-L20 is a compact integrated USB endoscope camera module for projects that need smooth 60fps visualization, local LED illumination and IP67 support.

The model is flexible, but customers should confirm FOV, focus range, lighting conditions, cable length and device structure before sample approval and mass production.

CTA

Still not sure whether SF-C1011USB-D3.9-720P60-L20 fits your device?

Send your application, actual working distance, preferred FOV, waterproof requirement, cable length and Type-C host information to SincereFull. Our team can help evaluate the correct endoscope camera module direction for your project.